Authors: D.I. Masse, J.A. Munroe and H.A. Jackson
Identifier: 
Download file: https://library.csbe-scgab.ca/docs/journal/36/36_3_185_ocr.pdf
Published in: CBE Journal » CBE Journal Volume 36 (1994)

Download RAW file: https://library.csbe-scgab.ca/docs/journal/36/36_3_185_raw.pdf
DOI:
Description: A mobile test rig to determine the air leakage characteristics of farm buildings was developed, con structed, and tested. This rig consisted of a trailer mounted 1.2 m diameter vane axial fan with a rated capacity of 14 m3/s at a static pressure of 60 Pa and an adjustable duct-to-building adapter. Air flow was measured using 20 Pitot tubes located in the duct. Initial tests on two dairy bams indicated air leakage rates in the order of 5 and 11 air changes per hour at a pressure differential across the building envelopes of 20 Pa.

Keywords:
Résumé:
Mots-clés:
Citation: D.I. Masse, J.A. Munroe and H.A. Jackson 1994. A MOBILE TEST RIG FOR DETERMINING THE AIR LEAKAGE CHARACTERISTICS OF FARM BUILDINGS. Canadian Agricultural Engineering 36(3):185-188.